KROHNE IFC 300 Signal Converter
Manufacturer: Krohne Inc
Mfg Product Code:
On Hand: 0
Signal converter for electromagnetic flowmeters
- All-round signal converter matches almost any application requirement
- Reliable measurements with extensive diagnostics of device and application
- Wide range of communication options including PROFINET
Highlights
- For operation with complete OPTIFLUX, WATERFLUX and OPTIPROBE flow sensor line
- For flow sensors over a diameter range of DN2.5...3000/ 1/10…120"
- Continuous measurement of volume flow and flow velocity Integrated conductivity measurement, mass flow (at constant density) and coil temperature
- High measuring accuracy and long-term stability: ±0.15% of measured value ± 1mm/s
- Optimal zero point stability independent from product properties
- Power supply via 100…230VAC (standard) or 24VDC or 24VAC/DC (optional)
- Superior process reliability thanks to standard integrated diagnostics: testing of device functions, check for compliance with specifications and application testing
- Available inputs and outputs: Current output (including HART®), pulse/frequency output, status output, control input and current input
- Communication interfaces for integration into third party systems via HART® (as standard), Modbus, FOUNDATION™ Fieldbus, PROFIBUS® and PROFINET IO
- Wide range of custody transfer approvals including OIMLR49-1 and R117-1, MI-001, MI-004 and MI-005
KROHNE IFC 300 Signal Converter
Specifications
Type | [4] C-Compact or [N] W-Wall Mount***Non-Hazardous Area Only or [H] F-Field Mount or [5] C / CAP-Compact (OPTIFLUX 7000 only) or [G] F / PF-Field Mount (TIDALFLUX 2000 only) or [R] RL-Rack Light |
Power Supply | [A] 100-230 VAC or [1] 12-24 VDC or [4] 24 VDC/AC or [0] 12-24 VDC ***Only for Profinet, includes 1xM12 (PS) connector or [8] 100-230 VAC ***Only for Profinet |
Hazardous Area Approvals | [0] None / General Purpose or [5] FM Class I DIV 2 or [4] Class I DIV 1 or [A] cCSAus OL*Canada Only or [C] CSA Class I DIV 2 *Canada Only |
Cable Connection | [46] 1/2" NPT or [06] 1 x M12, connector or [16] 2 x M12, connectors or [66] M20 x 1,5 or [B6] Strip: tag |
Custody Transfer | [0] Without or [1] Water, NMi OIML R49 *Q3 = fixed per size, R = 80: Other Q3 & R Values available on request or [A] Other than water, OIML R117 *Q3 = fixed per size, R = 80: Other Q3 & R Values available on request |
Process Diagnostics | [0] Standard or [4] Batchcontrolling |
Converter Housing | [10] Die-Cast Aluminum (Polyurethane Coated) or [10] Polyamide-Polycarbonate - W or [10] Die-Cast Aluminum (Polyurethane Coated) - F / PF or [20] 316 Stainless Steel - C or [20] 316 Stainless Steel - F or [30] Die-Cast Aluminum (Polyurethane Coated), Sealed for Custody Transfer or [40] 316 Stainless Steel, Sealed for Custody Transfer - C or [40] 316 Stainless Steel, Sealed for Custody Transfer - F or [50] Polyamide, Sealed for Custody Transfer - W or [E0] Die-Cast Aluminum (Polyurethane Coated) w/ Plastic Window or [F0] 316 Stainless Steel w/ Plastic Window - C or [F0] 316 Stainless Steel w/ Plastic Window - F |
Outputs - Communication | [1] 4-20 mA/HART + Pulse/Frequency + Status + Control *Standard or [2] Ex-i IO (current output active + pulse output passive) or [3] Ex-i IO (current output passive + pulse output passive) or [4] Current active + Pulse active or [6] Current active + Pulse passive or [7] Current active + Pulse Namur or [8] Current passive + Pulse active or [B] Current passive + Pulse passive or [C] Current passive + Pulse Namur or [D] Fieldbus IO: Profibus PA or [E] Fieldbus IO: Foundation Fieldbus or [F] Fieldbus IO: Profibus DP or [G] IO: RS485 Modbus or [N] Ethernet: Profinet |
First IO Module | [0] No module possible or [1] Ex-i IO (current output active + pulse output passive) or [2] Ex-i IO (current output passive + pulse output passive) or [8] Without IO module or [A] Current active or [B] Current passive or [C] Pulse active/high current or [E] Pulse passive/high current or [F] Pulse passive/Namur or [G] Control Input active/high current or [H] Control Input active/Namur or [K] Control Input passive/high current |
Second IO Module | [0] No module possible or [8] Without IO module or [A] Current active or [B] Current passive or [C] Pulse active/high current or [E] Pulse passive/high current or [F] Pulse passive/Namur or [G] Control Input active/high current or [H] Control Input active/Namur or [K] Control Input passive/high current |
Reference Method | [0] Standard or [1] Virtual Reference |
Tag Plate | [00] Without or [20] 316SS (120x46mm), Add Tag# or [30] 316SS (67x25mm), Add Tag# |