Laser Displacement Sensor (LE550UC1Q)
Manufacturer: Banner Engineering Corp
Mfg Product Code: 95377
Weight: 0.45 lb(s)
Laser Displacement Sensor
Features:
- Laser Displacement Sensor
- Range: 100-1000 mm
- Input:12-30 V dc
- Output: Analog: 0-10 V
- Discrete: NPN/PNP configurable
- Class 1 Laser
- Integral Quick-Disconnect
Laser Displacement Sensor (LE550UC1Q)
Laser Displacement Sensor
Brand_Name:Banner
Manufacturer Product Family:LE SERIES
Measurement Maximum:0
Max Off-State Leakage Current (µA):<200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP)
Min Operating Temperature:-20 °C
Max Operating Temperature:55 °C
Power/Current Consumption (exclusive of load):70 mA @ 24 V dc
Power Supply:12-30 VDC
Temperature Effect (mm/°C):#ERROR
Delay at Power-Up:2000 ms
Measurement Minimum:0
Ingress Protection:IP67
Sensing Beam:Visible Red Laser
Sensing Beam Wavelength:650
Housing Style:Rectangular
Max Sensing Distance:1000 mm
Sensing Mode (Detailed):Triangulation
Sensing Mode (General):Proximity
Device Type:Sensor
Housing Material_:Zinc Alloy Die-Cast
Feature: RS-232:No
Feature: RS-485:No
RS-422:No
Laser Classification:Class 1
Analog Output:0 to 10 VDC
Feature: IO Link:No
Feature: Wireless:No
Feature: Quick Disconnect:Yes
Quick Disconnect Type:M12
Max Op. Relative NC Humidity:90% @ 55 °C
Feature: Chemical Resistant:No
Storage Temp:-30 to 65 °C
Number of Pins:5
Adjustments:Push Button; Remote Teach
Feature: Timing (Hold/Delay):Yes
Input/Output:Analog & Discrete
Min Response Time:2 ms
Vibration:MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock:IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage PNP Outputs:< 3 V @ 100 mA
Analog Resolution/Discrete Repeatability:100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1
Max Discrete (Switched) Output (mA):100
Min Sensing Distance:100 mm
Min Window Size:10 mm
Remote Teach and Laser Control Input Impedence:18 kΩ min. (65 kΩ min at 5 V dc)
Discrete (Switched) Outputs:1 NPN/PNP Configurable
Max Measurement Range:500-1000 mm
Output Protection:Protected against continuous overload and short circuit
Profibus:No
Feature: Remote Teach:Yes
Output Saturation Voltage NPN Outputs:<1.6 V @ 100 mA
Analog Voltage Output Rating:2.5 kΩ min. load impedance
Supply Protection Circuitry:Protected against reverse polarity and transient overvoltages
Spot Size (@ Reference Distance):4.9 mm x 12.1 mm @ 1 m
Connection Type:Integral QD
Country of Origin:US
NEMA / UL:NEMA 6
Feature: Common Ethernet Protocol:No
Feature: Health/Marginal Signal Output:Yes
Feature: Laser Control:Yes
Feature: PC Configurable:No
Indicator Type:LCD/LED
Max Ambient Light:5000 lux
Warm-Up Time:10 min
Discrete Output Hysteresis:Auto Adjust
Alarm Output (mA):100
Analog Linearity:Lesser of Accuracy or 0.5% FS (±4.5 mm)
Specifications
Brand_Name | Banner |
Manufacturer Product Family | LE SERIES |
Measurement Maximum | 0 |
Max Off-State Leakage Current (µA) | <200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP) |
Min Operating Temperature | -20 °C |
Max Operating Temperature | 55 °C |
Power/Current Consumption (exclusive of load) | 70 mA @ 24 V dc |
Power Supply | 12-30 VDC |
Temperature Effect (mm/°C) | #ERROR |
Delay at Power-Up | 2000 ms |
Measurement Minimum | 0 |
Ingress Protection | IP67 |
Sensing Beam | Visible Red Laser |
Sensing Beam Wavelength | 650 |
Housing Style | Rectangular |
Max Sensing Distance | 1000 mm |
Sensing Mode (Detailed) | Triangulation |
Sensing Mode (General) | Proximity |
Device Type | Sensor |
Housing Material_ | Zinc Alloy Die-Cast |
Feature: RS-232 | No |
Feature: RS-485 | No |
RS-422 | No |
Laser Classification | Class 1 |
Analog Output | 0 to 10 VDC |
Feature: IO Link | No |
Feature: Wireless | No |
Feature: Quick Disconnect | Yes |
Quick Disconnect Type | M12 |
Max Op. Relative NC Humidity | 90% @ 55 °C |
Feature: Chemical Resistant | No |
Storage Temp | -30 to 65 °C |
Number of Pins | 5 |
Adjustments | Push Button; Remote Teach |
Feature: Timing (Hold/Delay) | Yes |
Input/Output | Analog & Discrete |
Min Response Time | 2 ms |
Vibration | MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G). |
Mechanical Shock | IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave |
Output Saturation Voltage PNP Outputs | < 3 V @ 100 mA |
Analog Resolution/Discrete Repeatability | 100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1 |
Max Discrete (Switched) Output (mA) | 100 |
Min Sensing Distance | 100 mm |
Min Window Size | 10 mm |
Remote Teach and Laser Control Input Impedence | 18 kΩ min. (65 kΩ min at 5 V dc) |
Discrete (Switched) Outputs | 1 NPN/PNP Configurable |
Max Measurement Range | 500-1000 mm |
Output Protection | Protected against continuous overload and short circuit |
Profibus | No |
Feature: Remote Teach | Yes |
Output Saturation Voltage NPN Outputs | <1.6 V @ 100 mA |
Analog Voltage Output Rating | 2.5 kΩ min. load impedance |
Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
Spot Size (@ Reference Distance) | 4.9 mm x 12.1 mm @ 1 m |
Connection Type | Integral QD |
Country of Origin | US |
NEMA / UL | NEMA 6 |
Feature: Common Ethernet Protocol | No |
Feature: Health/Marginal Signal Output | Yes |
Feature: Laser Control | Yes |
Feature: PC Configurable | No |
Indicator Type | LCD/LED |
Max Ambient Light | 5000 lux |
Warm-Up Time | 10 min |
Discrete Output Hysteresis | Auto Adjust |
Alarm Output (mA) | 100 |
Analog Linearity | Lesser of Accuracy or 0.5% FS (±4.5 mm) |