EPI, Thermal Mass Flow Meter, 3" X 6", Hydrogen

https://www.branom.com/web/image/product.template/541864/image_1920?unique=e86ac64
(0 review)

Manufacturer: Eldridge Products - EPI

Mfg Product Code: 8649MP-INT -SSS-000- DC24-MW050-S4049MTNZL-1RC-H2-CT2-MB

Weight: 10.0 lb(s)

On Hand: 0

8649MP - Hazardous Area In-line Style Flow Meter - 3/8" x 6"
INT - Integral Electronics - Standard two analog signal (4-20mA and 0-5VDC
flow & temperature) and one digital output (RS485
SSS - 316L stainless steel thermowells - 50Ω reference grade platinum
winding on ceramic rod with dielectric glass coating bonded by epoxy
buffer.
000 -No display
DC24 -24 VDC
MW050 -Gas Temperature Range: Ambient to 50°C/122°F
S4049MTNZL -3/8" SCH 40 Stainless Steel 316L x 6" Section - MNPT ends - Flow
Nozzle
1RC -1 Gas Range
H2 -HYDROGEN calibration against our certified 0.05% accurate Primary
Standard that is directly traceable to NIST. Enhanced accuracy
calibration is always optional.
CT2 -CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow
Transmitter (FE/FT or FIT with display); Approved for remote
electronics (FIT or FT) only with remote ACEX or DCEX feature; For use
in hazardous area locations; Class I Division 1, Group B, C, D; Class II
Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2
IP66; Ex d IIB+H2 IP66; T2; Ta = 0°C to 50°C
MB -RS485 Modbus RTU - Read & Write


Hydrogen calibration for 0-5 SCFM in a 3/8" Sch40 inline @ TBD temperature and 60 PSIG


    This combination does not exist.


    Product Datasheets

    Datasheet 1

    EPI, Thermal Mass Flow Meter, 3" X 6", Hydrogen

      4,034.56 4034.56 USD 4,034.56

      4,034.56

      Not Available For Sale

      This combination does not exist.


      8649MP - Hazardous Area In-line Style Flow Meter - 3/8" x 6"
      INT - Integral Electronics - Standard two analog signal (4-20mA and 0-5VDC
      flow & temperature) and one digital output (RS485
      SSS - 316L stainless steel thermowells - 50Ω reference grade platinum
      winding on ceramic rod with dielectric glass coating bonded by epoxy
      buffer.
      000 -No display
      DC24 -24 VDC
      MW050 -Gas Temperature Range: Ambient to 50°C/122°F
      S4049MTNZL -3/8" SCH 40 Stainless Steel 316L x 6" Section - MNPT ends - Flow
      Nozzle
      1RC -1 Gas Range
      H2 -HYDROGEN calibration against our certified 0.05% accurate Primary
      Standard that is directly traceable to NIST. Enhanced accuracy
      calibration is always optional.
      CT2 -CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow
      Transmitter (FE/FT or FIT with display); Approved for remote
      electronics (FIT or FT) only with remote ACEX or DCEX feature; For use
      in hazardous area locations; Class I Division 1, Group B, C, D; Class II
      Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2
      IP66; Ex d IIB+H2 IP66; T2; Ta = 0°C to 50°C
      MB -RS485 Modbus RTU - Read & Write


      Hydrogen calibration for 0-5 SCFM in a 3/8" Sch40 inline @ TBD temperature and 60 PSIG