RCVR PNP COMPLMNTRY THROUGH BEAM ULTRASONIC (T18VP6URQP)
Measurement Maximum:0
Max Off-State Leakage Current (µA):<1 µA @ 30 VDC
Min Operating Temperature:-40 °C
Max Operating Temperature:70 °C
Power/Current Consumption (exclusive of load):35 mA
Temperature Warm-up Drift upon Power-up:< 1.7% of the sensing distance upon power-up.
Power Supply:12-30 VDC
Delay at Power-Up:100 ms
Measurement Minimum:0
Ingress Protection:IP67
Sensing Beam:Ultrasonic
Housing Style:Rectangular w/ Threaded Mount
Max Sensing Distance:600 mm
Sensing Mode (Detailed):Receiver
Sensing Mode (General):Opposed
Device Type:Sensor
Housing Material_:PBT
Feature: RS-232:No
Feature: RS-485:No
RS-422:No
Feature: IO Link:No
Feature: Wireless:No
Feature: Quick Disconnect:Yes
Quick Disconnect Type:M12
Feature: Chemical Resistant:No
Number of Pins:4
Feature: Timing (Hold/Delay):No
Input/Output:Discrete
Barrel Diameter:18
Min Response Time:1 ms
Vibration:MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Feature: Ultrasonic:Yes
Output Saturation Voltage PNP Outputs:< 1.5 V @ 10 mA / <2.0 V @ 150 mA
Max Discrete (Switched) Output (mA):150 mA max. (each output) at 25°C, derated to 100 mA at 70°C (derate ≈ 1 mA per °C)
Feature: Clear Object Detection:Yes
Discrete (Switched) Outputs:PNP Complementary
Max Measurement Range:500-1000 mm
Output Protection:Protected against overload and short circuit conditions. No false pulse upon receiver power-up
SSI:No
Profibus:No
Output Saturation Voltage NPN Outputs:<1.5 V @ 10 mA / <2.0 V @ 150 mA
Supply Protection Circuitry:Protected against reverse polarity and transient overvoltages
Temp. Warm-up Drift (Notes 1):After 10 min, the apparent distance is < 0.3% of the actual position.
Temp. Warm-up Drift (Notes 2):After 25 min, the sensing position will be stable.
Mechanical Shock (Additional Comments):MIL-STD-202G, Meth. 213B, conditions H&I (Shock: 75G with unit operation: 100G for non-operation).
Connection Type:Pigtail QD
Country of Origin:US
NEMA / UL:NEMA 6P
Cord/Cable Length:0.15 m
Barrel Thread:M18
Feature: Common Ethernet Protocol:No
Feature: PC Configurable:No
Indicator Type:LED
Rep Rate:5 - 8 ms
Ultrasonic Frequency:230 kHz
Specifications
Measurement Maximum | 0 |
Max Off-State Leakage Current (µA) | <1 µA @ 30 VDC |
Min Operating Temperature | -40 °C |
Max Operating Temperature | 70 °C |
Power/Current Consumption (exclusive of load) | 35 mA |
Temperature Warm-up Drift upon Power-up | < 1.7% of the sensing distance upon power-up. |
Power Supply | 12-30 VDC |
Delay at Power-Up | 100 ms |
Measurement Minimum | 0 |
Ingress Protection | IP67 |
Sensing Beam | Ultrasonic |
Housing Style | Rectangular w/ Threaded Mount |
Max Sensing Distance | 600 mm |
Sensing Mode (Detailed) | Receiver |
Sensing Mode (General) | Opposed |
Device Type | Sensor |
Housing Material_ | PBT |
Feature: RS-232 | No |
Feature: RS-485 | No |
RS-422 | No |
Feature: IO Link | No |
Feature: Wireless | No |
Feature: Quick Disconnect | Yes |
Quick Disconnect Type | M12 |
Feature: Chemical Resistant | No |
Number of Pins | 4 |
Feature: Timing (Hold/Delay) | No |
Input/Output | Discrete |
Barrel Diameter | 18 |
Min Response Time | 1 ms |
Vibration | MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G). |
Feature: Ultrasonic | Yes |
Output Saturation Voltage PNP Outputs | < 1.5 V @ 10 mA / <2.0 V @ 150 mA |
Max Discrete (Switched) Output (mA) | 150 mA max. (each output) at 25°C, derated to 100 mA at 70°C (derate ≈ 1 mA per °C) |
Feature: Clear Object Detection | Yes |
Discrete (Switched) Outputs | PNP Complementary |
Max Measurement Range | 500-1000 mm |
Output Protection | Protected against overload and short circuit conditions. No false pulse upon receiver power-up |
SSI | No |
Profibus | No |
Output Saturation Voltage NPN Outputs | <1.5 V @ 10 mA / <2.0 V @ 150 mA |
Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
Temp. Warm-up Drift (Notes 1) | After 10 min, the apparent distance is < 0.3% of the actual position. |
Temp. Warm-up Drift (Notes 2) | After 25 min, the sensing position will be stable. |
Mechanical Shock (Additional Comments) | MIL-STD-202G, Meth. 213B, conditions H&I (Shock: 75G with unit operation: 100G for non-operation). |
Connection Type | Pigtail QD |
Country of Origin | US |
NEMA / UL | NEMA 6P |
Cord/Cable Length | 0.15 m |
Barrel Thread | M18 |
Feature: Common Ethernet Protocol | No |
Feature: PC Configurable | No |
Indicator Type | LED |
Rep Rate | 5 - 8 ms |
Ultrasonic Frequency | 230 kHz |