EPI SERIES 7240 Thermal Mass Flow Switch, 12" PROBE INSERTION, 3/4" OD
Manufacturer: Eldridge Products - EPI
Mfg Product Code: 7260‐INT‐SSS‐000‐ AC115‐MW050‐6012NA‐NA
Flow Switch Insertion Style - 3/4" OD Probe
Integral Electronics - standard outputs: 0-5VDC & 4-20mA (flow with optional temperature), RS485
ModbusRTU. 4-20mA FLOW enabled unless specified. Modbus is disabled.
316L stainless steel sensor. OPTIONAL - sensor with attenuating rod, sensor with particle sensor
shield, or Hastelloy® C-276 sensor
000‐No display
AC115‐MW050‐
6012NANA'‐ 3/4" OD x 12" Probe
No Agency Approvals
Trip point accuracy (Ref: 21°C)……………………..............1% of set point
Signal output Relay Contact High & Low……....…............…6 AMP @ 24VDC or 250VAC (Class A
Insulation)
Event Relay Rating…………………………………………................One with Frequency or Two, 1 AMP @ 30VDC
(33W)
Trip point accuracy........................................................................1.0% of set point
Repeatability......................................................................................0.5% of Full Scale
Sensor response time....................................................................1 second
Turn down ratio............................................................................100:1 minimum
Range (gas).......................................................................................0 - 15,000 SFPM / 0 - 4,572 NMPS
Range (liquid)..................................................................................0 - 300 SFPM / 0 - 91 NMPS
Electronics temperature range...............................................0 to 50°C (32 to 122°F), extended range
optional
Fluid temperature range..........................................................-40 to 200°C (-40 to 392°F), extended range
available
Gas temperature range.............................................................-40 to 200°C (-40 to 392°F), extended range
available
Gas pressure effect (liquid not applicable).......................Negligible over 20% of set point pressure
Pressure rating maximum.........................................................500 PSI - standard, >500 PSI - special
Input power requirement..........................................................24VDC @ 250mA
115VAC 50/60 Hz optional
230VAC 50/60 Hz optional
Flow Transmitter power requirements..............................5 Watts maximum
Flow Switch enclosure................................................................NEMA 4X, Class 1, Div 1, Groups B, C and D -
standard
Wetted materials...........................................................................316L Stainless Steel (Hastelloy optional)
EPI SERIES 7240 Thermal Mass Flow Switch, 12" PROBE INSERTION, 3/4" OD
Flow Switch Insertion Style - 3/4" OD Probe
Integral Electronics - standard outputs: 0-5VDC & 4-20mA (flow with optional temperature), RS485
ModbusRTU. 4-20mA FLOW enabled unless specified. Modbus is disabled.
316L stainless steel sensor. OPTIONAL - sensor with attenuating rod, sensor with particle sensor
shield, or Hastelloy® C-276 sensor
000‐No display
AC115‐MW050‐
6012NANA'‐ 3/4" OD x 12" Probe
No Agency Approvals
Trip point accuracy (Ref: 21°C)……………………..............1% of set point
Signal output Relay Contact High & Low……....…............…6 AMP @ 24VDC or 250VAC (Class A
Insulation)
Event Relay Rating…………………………………………................One with Frequency or Two, 1 AMP @ 30VDC
(33W)
Trip point accuracy........................................................................1.0% of set point
Repeatability......................................................................................0.5% of Full Scale
Sensor response time....................................................................1 second
Turn down ratio............................................................................100:1 minimum
Range (gas).......................................................................................0 - 15,000 SFPM / 0 - 4,572 NMPS
Range (liquid)..................................................................................0 - 300 SFPM / 0 - 91 NMPS
Electronics temperature range...............................................0 to 50°C (32 to 122°F), extended range
optional
Fluid temperature range..........................................................-40 to 200°C (-40 to 392°F), extended range
available
Gas temperature range.............................................................-40 to 200°C (-40 to 392°F), extended range
available
Gas pressure effect (liquid not applicable).......................Negligible over 20% of set point pressure
Pressure rating maximum.........................................................500 PSI - standard, >500 PSI - special
Input power requirement..........................................................24VDC @ 250mA
115VAC 50/60 Hz optional
230VAC 50/60 Hz optional
Flow Transmitter power requirements..............................5 Watts maximum
Flow Switch enclosure................................................................NEMA 4X, Class 1, Div 1, Groups B, C and D -
standard
Wetted materials...........................................................................316L Stainless Steel (Hastelloy optional)
Brand_Name:Eldridge
Measurement Minimum:0
Input Communication Protocol:4-20 mA, 2 Wire
Output Communication Protocol:4-20 mA / HART
Input Voltage:120 VAC
Ingress Protection:IP66
NEMA / UL:NEMA 4X
Specifications
Brand_Name | Eldridge |
Measurement Minimum | 0 |
Input Communication Protocol | 4-20 mA, 2 Wire |
Output Communication Protocol | 4-20 mA / HART |
Input Voltage | 120 VAC |
Ingress Protection | IP66 |
NEMA / UL | NEMA 4X |