25 Series Sanitary Transmitter, Tri Clamp 2", -14.7 psig to 335 psig
Manufacturer: Noshok Inc
Mfg Product Code: 254-16-14.7/335-vac-1-1-28
Weight: 3.5 lb(s)
25 Series Sanitary Transmitter, Tri Clamp 2", Range Adjustable from -14.7 psig to 335 psig, 0.2% of adjusted span, 4-20 mA/2-wire, 1/2 NPT Female
- Easy programming and range adjustment without test pressure via on-board display
- 4:1 turn down
- Active temperature compensation
- Hart® protocol output available
- All Stainless Steel housing and wetted parts
Applications:
- Food & dairy
- Chemical processing
- Pharmaceutical
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
25 Series Sanitary Transmitter, Tri Clamp 2", -14.7 psig to 335 psig
25 Series Sanitary Transmitter, Tri Clamp 2", Range Adjustable from -14.7 psig to 335 psig, 0.2% of adjusted span, 4-20 mA/2-wire, 1/2 NPT Female
Measurement Maximum:335.0
Process Connection Type:Tri-Clamp
Pressure Range:-14.7 psig to 335 psig
Product Unit of Measure:psig
Process Connection Size:2"
Process Connection Location:Bottom
Accuracy:0.2% of adjusted span
Case Material:316 SS
Wetted Material:316L SS
Measurement Minimum:-14.7
Output Communication Protocol:4-20 mA, 2-wire
Specifications
Measurement Maximum | 335.0 |
Process Connection Type | Tri-Clamp |
Pressure Range | -14.7 psig to 335 psig |
Product Unit of Measure | psig |
Process Connection Size | 2" |
Process Connection Location | Bottom |
Accuracy | 0.2% of adjusted span |
Case Material | 316 SS |
Wetted Material | 316L SS |
Measurement Minimum | -14.7 |
Output Communication Protocol | 4-20 mA, 2-wire |