Representative photo. Please check item description for details.

Watlow Immersion Heater Nitrogen, 480V, 6KW

https://www.branom.com/web/image/product.template/184346/image_1920?unique=43588b6
(0 review)

Manufacturer: Watlow Electric Manufacturing Company

Mfg Product Code: 2141-0910

Weight: 2.0 lb(s)

On Hand: 0


Flange Voltage: 480
Flange Wattage: 6,000
Watt Density: 17.8
B Dimension (Immersed element length calculated): 23.0625
Number of Elements: 6 Elements
Electrical Phase configuration: 3 Phase - Delta wiring
Number of Circuits: 1
Flange Size: 5 Inch Flange
Flange Class: 150 lb.
Flange Material: 304 Stainless Steel Flange
Sheath Material: 316 SS
Baffles? With Baffles
Baffle Orientation: U Configuration, Inlet Near Flange
Cold End Section below the Flange: 4.5000
Sheath Passivation? Yes
Process Sensor: No Process Sensor
Hi-Limit Sensor: Type K Thermocouple
Thermowell required? No
Mounting Orientation: Horizontal
Number of Hilimit Sensors (1 or 2): 1
First Hi-Limit Location: 15.0625
Stand-off Terminal Enclosure? Yes
Terminal Enclosure: Explosion/Moisture Resist. (non-certified) (standard)
CE Low Volt Directive required? No

  • Measurement Maximum
  • Process Connection Type
  • Measurement Minimum

This combination does not exist.


Product Datasheets

Datasheet 1

Watlow Immersion Heater Nitrogen, 480V, 6KW

  • Measurement Maximum
  • Process Connection Type
  • Measurement Minimum

6,205.00 6205.0 USD 6,205.00

6,205.00

Not Available For Sale

This combination does not exist.



Flange Voltage: 480
Flange Wattage: 6,000
Watt Density: 17.8
B Dimension (Immersed element length calculated): 23.0625
Number of Elements: 6 Elements
Electrical Phase configuration: 3 Phase - Delta wiring
Number of Circuits: 1
Flange Size: 5 Inch Flange
Flange Class: 150 lb.
Flange Material: 304 Stainless Steel Flange
Sheath Material: 316 SS
Baffles? With Baffles
Baffle Orientation: U Configuration, Inlet Near Flange
Cold End Section below the Flange: 4.5000
Sheath Passivation? Yes
Process Sensor: No Process Sensor
Hi-Limit Sensor: Type K Thermocouple
Thermowell required? No
Mounting Orientation: Horizontal
Number of Hilimit Sensors (1 or 2): 1
First Hi-Limit Location: 15.0625
Stand-off Terminal Enclosure? Yes
Terminal Enclosure: Explosion/Moisture Resist. (non-certified) (standard)
CE Low Volt Directive required? No


Measurement Maximum:0
Process Connection Type:ASME B16.5 150#
Measurement Minimum:0


Specifications

Measurement Maximum 0
Process Connection Type ASME B16.5 150#
Measurement Minimum 0