Measurement Maximum:0
Max Off-State Leakage Current (µA):<200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP)
Analog Current Output Rating:1 to 500 Ω impedance
Min Operating Temperature:-20 °C
Max Operating Temperature:55 °C
Power/Current Consumption (exclusive of load):70 mA @ 24 V dc
Temperature Effect (mm/°C):#ERROR!
Delay at Power-Up:2000 ms
Measurement Minimum:0
Ingress Protection:IP67
Housing Style:Rectangular
Max Sensing Distance:1000 mm
Feature: RS-232:No
Feature: RS-485:No
RS-422:No
Feature: IO Link:No
Feature: Wireless:No
Feature: Quick Disconnect:No
Max Op. Relative NC Humidity:90% @ 55 °C
Feature: Chemical Resistant:No
Number of Pins:5
Adjustments:Push Button; Remote Teach
Feature: Timing (Hold/Delay):No
Input/Output:Discrete
Min Response Time:2 ms
Analog Resolution/Discrete Repeatability:100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1
Max Discrete (Switched) Output (mA):100
Min Sensing Distance:100 mm
Min Window Size:1 mm
Max Measurement Range:500-1000 mm
Output Protection:Protected against continuous overload and short circuit
SSI:No
Profibus:No
Feature: Remote Teach:Yes
Output Saturation Voltage NPN Outputs:<1.6 V @ 100 mA
Analog Voltage Output Rating:10mA Max
Supply Protection Circuitry:Protected against reverse polarity and transient overvoltages
Connection Type:Cable
Country of Origin:US
NEMA / UL:NEMA 6
Cord/Cable Length:2 m
Feature: Common Ethernet Protocol:No
Feature: Laser Control:Yes
Feature: PC Configurable:No
Indicator Type:LCD/LED
Max Ambient Light:5000 lux
Warm-Up Time:10 min
Discrete Output Hysteresis:Auto Adjust
Specifications
Measurement Maximum | 0 |
Max Off-State Leakage Current (µA) | <200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP) |
Analog Current Output Rating | 1 to 500 Ω impedance |
Min Operating Temperature | -20 °C |
Max Operating Temperature | 55 °C |
Power/Current Consumption (exclusive of load) | 70 mA @ 24 V dc |
Temperature Effect (mm/°C) | #ERROR! |
Delay at Power-Up | 2000 ms |
Measurement Minimum | 0 |
Ingress Protection | IP67 |
Housing Style | Rectangular |
Max Sensing Distance | 1000 mm |
Feature: RS-232 | No |
Feature: RS-485 | No |
RS-422 | No |
Feature: IO Link | No |
Feature: Wireless | No |
Feature: Quick Disconnect | No |
Max Op. Relative NC Humidity | 90% @ 55 °C |
Feature: Chemical Resistant | No |
Number of Pins | 5 |
Adjustments | Push Button; Remote Teach |
Feature: Timing (Hold/Delay) | No |
Input/Output | Discrete |
Min Response Time | 2 ms |
Analog Resolution/Discrete Repeatability | 100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1 |
Max Discrete (Switched) Output (mA) | 100 |
Min Sensing Distance | 100 mm |
Min Window Size | 1 mm |
Max Measurement Range | 500-1000 mm |
Output Protection | Protected against continuous overload and short circuit |
SSI | No |
Profibus | No |
Feature: Remote Teach | Yes |
Output Saturation Voltage NPN Outputs | <1.6 V @ 100 mA |
Analog Voltage Output Rating | 10mA Max |
Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
Connection Type | Cable |
Country of Origin | US |
NEMA / UL | NEMA 6 |
Cord/Cable Length | 2 m |
Feature: Common Ethernet Protocol | No |
Feature: Laser Control | Yes |
Feature: PC Configurable | No |
Indicator Type | LCD/LED |
Max Ambient Light | 5000 lux |
Warm-Up Time | 10 min |
Discrete Output Hysteresis | Auto Adjust |